CMS9200 Patient Monitor

Functions:

  • ECG: Heart rate (HR), ECG waveform, arrhythmia, and ST-segment analysis.
  • RESP: Respiration rate (RR), respiration waveform.
  • SpO2: Pulse oxygen saturation (SpO2), plethysmogram (PLETH) waveform, pulse rate (PR), bar graph.
  • NIBP: Systolic pressure (SYS), diastolic pressure (DIA), mean pressure (MEAN).
  • TEMP: T1, T2, TD.

 

Main Features:

  • Display Mode: 15” color TFT LCD with high-resolution.
  • Patient Compatibility: Suitable for adults, pediatric, and neonatal for all-round monitoring.
  • Multilingual Interface: Operates in Chinese and English, with additional languages available.
  • Customizable Display: Waveform and data can be set optionally.
  • Data Storage: Capable of storing 72-hour trend data and reviewing 40-second holographic waveforms.
  • ECG Display: Full-lead ECG display with 7-lead ECG displays in a single screen.
  • Safety Features: Anti-high frequency surgical unit and defibrillation-proof with special leads.
  • Advanced SpO2 Technology: Digital SpO2 technology with strong anti-interference and anti-weak filling capability.
  • NIBP Review: Stores up to 400 NIBP data points.
  • Networking Capability: Connects to central monitoring stations, allows other bed observations, and supports software updates via wireless and wired modes.
  • Uninterrupted Monitoring: Built-in rechargeable battery.
  • Built-in Printer: Optional feature for printing patient data.
  • Optional Parameters: Includes IBP, EtCO2, and thermal printer.

 

Technical Specifications:

 

Safety Classification:

  • Type of Protection: Class I.
  • Degree of Protection Against Electroshock: Type CF defibrillation-proof applied part.
  • Degree of Protection Against Ingress of Water: IPX0.

 

Environment Requirements:

  • Working Temperature: 5~40ºC.
  • Storage Temperature: -40~+55ºC.
  • Working Humidity: 30%~75%.
  • Storage Humidity: ≤95% (no coagulation).

 

Power Supply:

  • Power Supply: AC100~240V, 50/60Hz.
  • Maximal Input Power: 150VA.
  • Battery Working Time: 90 minutes.

 

Display:

  • Waveform Display: 8-channel waveform on a single screen.
  • Customizable Color: Waveform and parameter colors can be set.
  • Waveform and Parameter Selection: Adjustable waveform positions and parameter selections.

 

Alarm:

  • Alarm Items: Technical alarms, 71 physiological alarms, and 60 arrhythmia alarms.
  • Prompt Mode: Visible, audible, and character alarms (3 alarm levels).

 

Trend Review:

  • Time: 480-hour trend review, 2400 BP data groups review.
  • Review Mode: Trend graph and trend table.
  • SD Card Review: 72-hour ECG waveform review.

 

Network:

  • Network Mode: Wired, WiFi, 3G.
  • Connection Contents: Connects to central monitor system via LAN or WAN; view bed.
  • Software Updating: Network and U disk updating.

 

ECG:

  • Lead Mode: 3-lead or 5-lead.
  • Lead Selection: I, II, III, aVR, aVF, aVL, V.
  • Gain: ×0.25, ×0.5, ×1, ×2.
  • Scan Speed: 12.5mm/s, 25mm/s, 50mm/s.
  • HR Measurement Range: Adult – 15~300bpm, Pediatric and neonatal – 15~350bpm.
  • ST Segment Monitoring: -2.0mV~+2.0mV with ±0.04mV or ±10% accuracy.
  • Arrhythmia Analysis: 13 types.

 

Respiration:

  • Method: R-F (RA-LL) Impedance.
  • Respiration Rate Range: 0~120 rpm.
  • Accuracy: ±2 rpm.
  • Apnea Alarm: 10~40 s.
  • Scan Speed: 6.25mm/s, 12.5mm/s, 25mm/s.

 

NIBP:

  • Method: Oscillometry.
  • Measurement Range:
  • Adult: Systolic – 40~270mmHg, Diastolic – 10~215 mmHg, Mean – 20~235 mmHg
  • Pediatric: Systolic – 40~200mmHg, Diastolic – 10~150 mmHg, Mean – 20~165 mmHg
  • Neonate: Systolic – 40~135 mmHg, Diastolic – 10~100 mmHg, Mean – 20~110 mmHg
  • Accuracy: ±5mmHg, maximal standard deviation 8mmHg.
  • Over-Pressure Protection: Adult Mode: 297±3 mmHg, Pediatric Mode: 240±3 mmHg, Neonatal Mode: 147±3 mmHg.

 

Temperature:

  • Channels: Dual-channel.
  • Measurement Range: 0~50ºC.
  • Accuracy: 0.1ºC.
  • Resolution: 0.1ºC.
  • Updating Time: About 1s.

 

SpO2:

  • Measurement Range: 0~100%.
  • Accuracy: 70%~100%: ±2%; 0%~69%: unspecified.
  • PR Range: 0~250 bpm.
  • PR Accuracy: ±2 bpm or ±2%, whichever is greater.

 

Optional Printer:

  • Waveform: 2-channel.
  • Print Width: 48mm.
  • Paper Speed: 25mm/s, 50mm/s.

 

EtCO2 (Optional):

  • Method: Sidestream or Mainstream.
  • CO2 Range: 0~150 mmHg.
  • Resolution: 0.1 mm Hg: 0 to 69 mm Hg, 0.25 mm Hg: 70 to 150 mm Hg.
  • Accuracy: 0 – 40 mm Hg: ±2 mm Hg, 41 – 70 mm Hg :±5%,  71 – 100 mm Hg :±8%, 101 – 150 mm Hg :±10%.
  • Respiration Rate>80BPM: ±12%
  • AwRR Range: 0~150 rpm.
  • Apnea Alarm: Yes.

 

IBP (Optional):

  • Channels: Dual-channel.
  • Labels: ART, PA, CVP, RAP, LAP, ICP, P1, P2.
  • Measurement Range: -10~300 mm Hg.
  • Resolution: 1 mm Hg.
  • Accuracy: ±2% or 1 mm Hg, whichever is greater.